Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Merseyside · L24

Fire-Rated Curtain Walling for Speke buildings

From the L24 district outwards, we arrange fire-rated curtain walling for buildings across Speke, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60L24England

Quote for Speke

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Speke

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Slab-edge fire-stopping and cavity barriers to the design
  • Tested fire-rated curtain wall systems
  • Fire-rated zones within mixed facades
  • Spandrel and opaque panel coordination

How we work in Speke

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Rated systems, not just rated glass

Every quote in Speke identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Work around occupied buildings

We can phase work in Speke around residents, staff or pupils, with out-of-hours options.

Before you order fire-rated curtain walling: what matters

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Areas we cover around Speke

Survey visits can be arranged anywhere in Speke, including the L24, L26, L19, L25 districts, and in nearby Halewood, Garston, Runcorn. Liverpool, around 12 km from Speke, is the largest town in the same coverage area.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Speke

Sector guides below cover industrial units, offices and other buildings in Speke.

Fire-Rated Curtain Walling: Speke questions

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Do you carry out fire-rated curtain walling in Speke?

Yes. We survey and install in Speke and across Merseyside, including the L24 district and nearby Halewood.

Can you price fire-rated curtain walling in Speke from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Speke

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Speke to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote