Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Leicestershire · LE2

Fire-Rated Curtain Walling — Oadby and LE2

From the LE2 district outwards, we arrange fire-rated curtain walling for buildings across Oadby, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60LE2England

Quote for Oadby

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling in Oadby: what's included

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Tested fire-rated curtain wall systems
  • External-grade fire glass
  • Spandrel and opaque panel coordination
  • Handover evidence for the building record

How we work in Oadby

Honest about unknowns

If an existing frame in a Oadby building has no traceable evidence, we say so and price the options rather than guess.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Rated systems, not just rated glass

Every quote in Oadby identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

What to check before ordering fire-rated curtain walling in Oadby

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Areas we cover around Oadby

We cover Oadby and the surrounding postcode districts, including LE2, LE18, LE5, LE1. Nearby towns we also serve include Wigston, Leicester, Market Harborough. Oadby is about 5 km from Leicester, the largest town in our Leicestershire coverage.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Sectors we cover in Oadby

Fire-rated curtain walling applies to many building types in Oadby, including schools and colleges and care homes.

Fire-Rated Curtain Walling: Oadby questions

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Do you carry out fire-rated curtain walling in Oadby?

Yes. We survey and install in Oadby and across Leicestershire, including the LE2 district and nearby Wigston.

Which rules apply to fire-rated glazing in Oadby?

Building work in Oadby follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Oadby

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Oadby confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote