Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →When a fire strategy, inspection report or building control comment in Gravesend calls for glazing tested to resist fire, our fire-rated curtain walling service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
Our Kent coverage takes in Gravesend (DA12, DA11, DA10, RM18, RM17) and the neighbouring towns of Grays, Strood, South Ockendon. Maidstone, around 22 km from Gravesend, is the largest town in the same coverage area.
We can phase work in Gravesend around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Gravesend budgets are not open-ended.
If an existing frame in a Gravesend building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated curtain walling applies to many building types in Gravesend, including care homes and blocks of flats.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Gravesend and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.