Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater Manchester · WN7

Fire-Rated Curtain Walling for Leigh buildings

When a fire strategy, inspection report or building control comment in Leigh calls for glazing tested to resist fire, our fire-rated curtain walling service covers survey, supply and installation.

E 30 – EI 60WN7England

Quote for Leigh

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Leigh

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Spandrel and opaque panel coordination
  • Tested fire-rated curtain wall systems
  • Fire-rated zones within mixed facades
  • External-grade fire glass

What to check before ordering fire-rated curtain walling in Leigh

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

Which rules apply to fire-rated curtain walling in Leigh?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Where we work around Leigh

Our Greater Manchester coverage takes in Leigh (WN7, M46, M29) and the neighbouring towns of Atherton, Tyldesley, Golborne. Leigh is about 19 km from Manchester, the largest town in our Greater Manchester coverage.

What you can expect in Leigh

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Rated systems, not just rated glass

Every quote in Leigh identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Honest about unknowns

If an existing frame in a Leigh building has no traceable evidence, we say so and price the options rather than guess.

Sectors we cover in Leigh

Fire-rated curtain walling applies to many building types in Leigh, including retail and leisure units and public buildings.

FAQs for Leigh

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Do you carry out fire-rated curtain walling in Leigh?

Yes. We survey and install in Leigh and across Greater Manchester, including the WN7 district and nearby Atherton.

How quickly can you survey in Leigh?

Survey timing in Leigh depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Leigh

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Leigh to measure, record existing marks and check the frames and substrate.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote