Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater Manchester · SK14

Fire-Rated Curtain Walling for Hyde buildings

If a building in Hyde needs fire-rated curtain walling, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60SK14England

Quote for Hyde

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Hyde

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • External-grade fire glass
  • Handover evidence for the building record
  • Slab-edge fire-stopping and cavity barriers to the design
  • Spandrel and opaque panel coordination

Key checks for Hyde projects

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Where we work around Hyde

Our Greater Manchester coverage takes in Hyde (SK14, M34, SK16, SK15, OL7, OL6) and the neighbouring towns of Denton, Dukinfield, Stalybridge. Hyde is about 11 km from Manchester, the largest town in our Greater Manchester coverage.

How we work in Hyde

Honest about unknowns

If an existing frame in a Hyde building has no traceable evidence, we say so and price the options rather than guess.

Work around occupied buildings

We can phase work in Hyde around residents, staff or pupils, with out-of-hours options.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Hyde budgets are not open-ended.

Building types we cover in Hyde

Sector guides below cover public buildings, industrial units and other buildings in Hyde.

FAQs for Hyde

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Do you carry out fire-rated curtain walling in Hyde?

Yes. We survey and install in Hyde and across Greater Manchester, including the SK14 district and nearby Denton.

Can you price fire-rated curtain walling in Hyde from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Hyde

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Hyde confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote