Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SW1

Fire-Rated Curtain Walling in Westminster

If a building in Westminster needs fire-rated curtain walling, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60SW1England

Quote for Westminster

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling in Westminster: what's included

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • External-grade fire glass
  • Fire-rated zones within mixed facades
  • Spandrel and opaque panel coordination
  • Slab-edge fire-stopping and cavity barriers to the design

Before you order fire-rated curtain walling: what matters

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Westminster coverage and nearby towns

Survey visits can be arranged anywhere in Westminster, including the SW1, SW1A, W1M, SW1X, EC1A, EC1M districts, and in nearby Pimlico, London, Chelsea. Westminster is one of the Greater London districts we cover.

How we work in Westminster

Rated systems, not just rated glass

Every quote in Westminster identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Honest about unknowns

If an existing frame in a Westminster building has no traceable evidence, we say so and price the options rather than guess.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Westminster budgets are not open-ended.

Sectors we cover in Westminster

Sector guides below cover blocks of flats, student accommodation and other buildings in Westminster.

Questions about fire-rated curtain walling in Westminster

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

How quickly can you survey in Westminster?

Survey timing in Westminster depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Do you carry out fire-rated curtain walling in Westminster?

Yes. We survey and install in Westminster and across Greater London, including the SW1 district and nearby Pimlico.

Related

Related services in Westminster

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Westminster job runs

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Westminster to measure, record existing marks and check the frames and substrate.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote