Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →Looking for fire-rated curtain walling in Southall? We survey, supply and install tested fire-rated glazing for offices, schools and colleges and other buildings in and around Southall, including the UB1 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Our Greater London coverage takes in Southall (UB1, UB2, UB18, W7, UB4, TW5) and the neighbouring towns of Greenford, Heston, Hayes. Southall is one of the Greater London districts we cover.
If an existing frame in a Southall building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Southall budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover offices, schools and colleges and other buildings in Southall.
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in Southall and across Greater London, including the UB1 district and nearby Greenford.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Southall to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.