Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · EN1

Fire-Rated Curtain Walling for Enfield buildings

We provide fire-rated curtain walling in Enfield and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 60EN1England

Quote for Enfield

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling in Enfield: what's included

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Handover evidence for the building record
  • Spandrel and opaque panel coordination
  • Tested fire-rated curtain wall systems
  • Fire-rated zones within mixed facades

Enfield coverage and nearby towns

Our Greater London coverage takes in Enfield (EN1, EN2, EN3, N21, N9, N14) and the neighbouring towns of Edmonton, Tottenham, Wood Green. Enfield sits within our Greater London coverage, alongside Edmonton.

Key checks for Enfield projects

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

What every Enfield quote includes

Honest about unknowns

If an existing frame in a Enfield building has no traceable evidence, we say so and price the options rather than guess.

Work around occupied buildings

We can phase work in Enfield around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Enfield identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Sectors we cover in Enfield

Sector guides below cover blocks of flats, retail and leisure units and other buildings in Enfield.

Questions about fire-rated curtain walling in Enfield

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Can you price fire-rated curtain walling in Enfield from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Which rules apply to fire-rated glazing in Enfield?

Building work in Enfield follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Enfield

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Enfield job runs

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Enfield and check what the existing frames can accept.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote