Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Gloucestershire · GL7

Fire-Rated Curtain Walling across Cirencester

From the GL7 district outwards, we arrange fire-rated curtain walling for buildings across Cirencester, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60GL7England

Quote for Cirencester

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Cirencester

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Spandrel and opaque panel coordination
  • Slab-edge fire-stopping and cavity barriers to the design
  • Handover evidence for the building record
  • External-grade fire glass

Before you order fire-rated curtain walling: what matters

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

Cirencester coverage and nearby towns

We cover Cirencester and the surrounding postcode districts, including GL7. Nearby towns we also serve include Stroud, Cheltenham, Swindon. Gloucester, around 25 km from Cirencester, is the largest town in the same coverage area.

What you can expect in Cirencester

Rated systems, not just rated glass

Every quote in Cirencester identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Cirencester budgets are not open-ended.

Cirencester building types

We can survey and quote for care homes, offices and other building types in Cirencester.

Fire-Rated Curtain Walling: Cirencester questions

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Do you work on occupied buildings in Cirencester?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Cirencester?

Building work in Cirencester follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Cirencester

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Cirencester and check what the existing frames can accept.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote