Fire-Rated Curtain Walling in Dyfed
Our Dyfed fire-rated curtain walling service covers survey, supply and installation to the tested details, documented on handover.
Quote for Dyfed
Tell us what you need. We reply with next steps and a guide price.
What our fire-rated curtain walling service includes in Dyfed
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
- Slab-edge fire-stopping and cavity barriers to the design
- Handover evidence for the building record
- Fire-rated zones within mixed facades
Fire-Rated Curtain Walling by town in Dyfed
Across Dyfed we can survey in Llanelli, Ammanford and every district in the SA, SY postcode areas. We also cover Carmarthen, Aberystwyth, Haverfordwest, Pembroke Dock, Milford Haven.
Key checks for Dyfed projects
Thermal and acoustic
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
External-grade glass
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
Boundaries
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Regulations for Dyfed projects
Wales Which rules apply?
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.
Questions from Dyfed clients
Do you work on high-rise buildings?
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Can fire glass be used in double-glazed units?
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
When does curtain walling need to be fire-rated?
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Do you cover all of Dyfed?
Yes. We take enquiries from across Dyfed, including Llanelli and Ammanford, and arrange surveys to suit your programme.
Related services in Dyfed
From enquiry to handover in Dyfed
Share the details
Send the fire strategy extract, inspection report or a few photos of the openings.
Measure and check
We measure each opening in Dyfed and check what the existing frames can accept.
Written proposal
We set out the system, glass, evidence and programme, with a fixed price.
Complete and document
Work is completed to the manufacturer's details and documented for your records.