Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →From the G61 district outwards, we arrange fire-rated curtain walling for buildings across Bearsden, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
Coverage around Bearsden includes the G61, G15, G13, G62, G23, G20 districts and nearby Clydebank, Renfrew, Bishopbriggs. Bearsden is the main town we cover in Dunbartonshire.
After survey you get a fixed written quote for the agreed scope, so Bearsden budgets are not open-ended.
We can phase work in Bearsden around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Fire-rated curtain walling applies to many building types in Bearsden, including industrial units and blocks of flats.
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Bearsden and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.