Dorset fire-rated curtain walling
Fire-rated curtain walling across Dorset covers 36 postcode districts in the BH, DT, SP, GY postcode areas. Every job is built around a tested system.
Quote for Dorset
Tell us what you need. We reply with next steps and a guide price.
Fire-Rated Curtain Walling: what you get in Dorset
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
- Handover evidence for the building record
- Fire-rated zones within mixed facades
- Tested fire-rated curtain wall systems
Before you order in Dorset
Boundaries
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Slab edges
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Higher-risk buildings
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
Fire-Rated Curtain Walling by town in Dorset
Our Dorset coverage spans 36 postcode districts across the BH, DT, SP, GY postcode areas.
Regulations for Dorset projects
England Which rules apply?
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
FAQs for Dorset
Can you add fire-rated zones to existing curtain walling?
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
When does curtain walling need to be fire-rated?
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Can fire glass be used in double-glazed units?
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
Can you survey anywhere in Dorset?
Yes. We can arrange surveys anywhere in Dorset, including Bournemouth and Poole, Weymouth, Christchurch.
Related services in Dorset
From enquiry to handover in Dorset
Share the details
Send the fire strategy extract, inspection report or a few photos of the openings.
Site visit
A survey in Dorset confirms sizes, access, existing evidence and fixing conditions.
Written proposal
We set out the system, glass, evidence and programme, with a fixed price.
Install and hand over
Installation to the system details, then a handover pack with photographs and evidence.