Fire-Rated Curtain Walling for County Fermanagh buildings

Fire-rated curtain walling across County Fermanagh covers 1 postcode district in the BT postcode areas. Every job is built around a tested system.

E 30 – EI 60Northern IrelandBT

Quote for County Fermanagh

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling: what you get in County Fermanagh

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Handover evidence for the building record
  • External-grade fire glass
  • Tested fire-rated curtain wall systems

What to check before ordering in County Fermanagh

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Slab edges

The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.

Places we cover in County Fermanagh

We cover fire-rated curtain walling in Enniskillen and across County Fermanagh, including Lisnaskea, Irvinestown.

Northern Ireland rules for fire glazing

Northern Ireland Which rules apply?

In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.

Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.

Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.

Questions from County Fermanagh clients

Do you work on high-rise buildings?

We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Can you survey anywhere in County Fermanagh?

Yes. We can arrange surveys anywhere in County Fermanagh, including Enniskillen and Lisnaskea, Irvinestown.

Related

Related services in County Fermanagh

Process

How a County Fermanagh job runs

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Site visit

A survey in County Fermanagh confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote