Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →For Falmouth buildings, we supply, replace and check fire-rated curtain walling wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
Whether the building is in central Falmouth or the wider TR11, TR10 districts, we can survey and quote. We also cover Truro, Redruth, Camborne. Truro, around 14 km from Falmouth, is the largest town in the same coverage area.
After survey you get a fixed written quote for the agreed scope, so Falmouth budgets are not open-ended.
If an existing frame in a Falmouth building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for retail and leisure units, care homes and other building types in Falmouth.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Falmouth follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Falmouth confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.