Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Berkshire · SL1

Fire-Rated Curtain Walling in Slough

We provide fire-rated curtain walling in Slough and across Berkshire, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 60SL1England

Quote for Slough

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated curtain walling in Slough

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • External-grade fire glass
  • Tested fire-rated curtain wall systems
  • Spandrel and opaque panel coordination
  • Handover evidence for the building record

Before you order fire-rated curtain walling: what matters

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

External-grade glass

External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Slough coverage and nearby towns

Our Berkshire coverage takes in Slough (SL1, SL3, SL4, SL2) and the neighbouring towns of Windsor, Maidenhead, Gerrards Cross. Reading, around 27 km from Slough, is the largest town in the same coverage area.

What you can expect in Slough

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Rated systems, not just rated glass

Every quote in Slough identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Building types we cover in Slough

We can survey and quote for student accommodation, offices and other building types in Slough.

Questions about fire-rated curtain walling in Slough

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Do you carry out fire-rated curtain walling in Slough?

Yes. We survey and install in Slough and across Berkshire, including the SL1 district and nearby Windsor.

Which rules apply to fire-rated glazing in Slough?

Building work in Slough follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Slough

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

From enquiry to handover in Slough

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Site visit

A survey in Slough confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote