Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
West Midlands · WV11

Aluminium Fire-Rated Screens across Wednesfield

For Wednesfield buildings, we supply, replace and check aluminium fire-rated screens wherever the fire strategy depends on it, working to the tested system rather than the glass alone.

E 30 – EI 60WV11England

Quote for Wednesfield

Tell us what you need. We reply with next steps and a guide price.

What our aluminium fire-rated screens service includes in Wednesfield

Aluminium fire-rated screens are glazed walls built from aluminium profiles that have been tested with fire-resistant glass and insulating inserts. They suit offices, healthcare and education buildings that want a clean, modern frame matching the rest of the glazing.

  • Tested aluminium fire screen systems
  • Integrity and insulating glass to the system schedule
  • Fire-stopping and perimeter details
  • Handover evidence

What every Wednesfield quote includes

Work around occupied buildings

We can phase work in Wednesfield around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Wednesfield identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Wednesfield budgets are not open-ended.

Key checks for Wednesfield projects

Ratings available

Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.

Inserts make the rating

Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.

Matching non-rated glazing

Aluminium fire screens can be visually matched to non-rated partitions elsewhere, so a floor reads as one design while only some walls are fire-rated.

Wednesfield coverage and nearby towns

Our West Midlands coverage takes in Wednesfield (WV11, WV1, WV12, WV2, WV13, WV14) and the neighbouring towns of Willenhall, Wolverhampton, Bloxwich. Wednesfield is about 18 km from Birmingham, the largest town in our West Midlands coverage.

Which rules apply to aluminium fire-rated screens in Wednesfield?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Wednesfield building types

Sector guides below cover schools and colleges, public buildings and other buildings in Wednesfield.

Questions about aluminium fire-rated screens in Wednesfield

Can aluminium fire screens be used outside?

Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.

Will the frames match our other glazing?

Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.

How quickly can you survey in Wednesfield?

Survey timing in Wednesfield depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Which rules apply to fire-rated glazing in Wednesfield?

Building work in Wednesfield follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Wednesfield

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

From enquiry to handover in Wednesfield

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Wednesfield and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote