Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the NE8 district outwards, we arrange aluminium fire-rated screens for buildings across Gateshead, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Gateshead building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Gateshead identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Coverage around Gateshead includes the NE8, NE1, NE10, NE2, NE6, NE4 districts and nearby Newcastle upon Tyne, Felling, Gosforth. Gateshead lies roughly 1 km from Newcastle upon Tyne, within our Tyne and Wear coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, offices and other buildings in Gateshead.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
Yes. We survey and install in Gateshead and across Tyne and Wear, including the NE8 district and nearby Newcastle upon Tyne.
Survey timing in Gateshead depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Gateshead confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.