Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the NN16 district outwards, we arrange aluminium fire-rated screens for buildings across Kettering, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
Every quote in Kettering identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Kettering around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Aluminium fire screens can be visually matched to non-rated partitions elsewhere, so a floor reads as one design while only some walls are fire-rated.
Head details and fixing centres come from the system documentation, especially beneath long-span slabs.
Survey visits can be arranged anywhere in Kettering, including the NN16 districts, and in nearby Wellingborough, Corby, Rushden. Northampton, around 20 km from Kettering, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for public buildings, schools and colleges and other building types in Kettering.
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Kettering to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.