Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Northamptonshire · NN11

Daventry aluminium fire-rated screens

If a building in Daventry needs aluminium fire-rated screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60NN11England

Quote for Daventry

Tell us what you need. We reply with next steps and a guide price.

What our aluminium fire-rated screens service includes in Daventry

Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.

  • Handover evidence
  • Tested aluminium fire screen systems
  • Integrity and insulating glass to the system schedule
  • Anodised and powder-coated finishes

Daventry coverage and nearby towns

Our Northamptonshire coverage takes in Daventry (NN11) and the neighbouring towns of Rugby, Northampton, Royal Leamington Spa. Daventry is about 19 km from Northampton, the largest town in our Northamptonshire coverage.

What to check before ordering aluminium fire-rated screens in Daventry

Ratings available

Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.

External use

Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.

Inserts make the rating

Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.

Which rules apply to aluminium fire-rated screens in Daventry?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

How we work in Daventry

Honest about unknowns

If an existing frame in a Daventry building has no traceable evidence, we say so and price the options rather than guess.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Rated systems, not just rated glass

Every quote in Daventry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Daventry building types

We can survey and quote for public buildings, schools and colleges and other building types in Daventry.

Aluminium Fire-Rated Screens: Daventry questions

Is aluminium suitable for fire-rated glazing?

Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.

Will the frames match our other glazing?

Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.

Do you work on occupied buildings in Daventry?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Daventry?

Building work in Daventry follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Daventry

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Site visit

A survey in Daventry confirms sizes, access, existing evidence and fixing conditions.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote