Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →For Pimlico buildings, we supply, replace and check aluminium fire-rated screens wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
If an existing frame in a Pimlico building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
Whether the building is in central Pimlico or the wider SW1, SW8, SW1A, W1M, SW1X, SE11 districts, we can survey and quote. We also cover Westminster, Battersea, Chelsea. Pimlico sits within our Greater London coverage, alongside Westminster.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Aluminium fire-rated screens applies to many building types in Pimlico, including offices and hotels.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
30 and 60-minute ratings are common, in integrity or insulation classes depending on the glass. We confirm availability for the sizes you need.
Survey timing in Pimlico depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Pimlico and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.