Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the BT51 district outwards, we arrange aluminium fire-rated screens for buildings across Coleraine, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Aluminium fire-rated screens are glazed walls built from aluminium profiles that have been tested with fire-resistant glass and insulating inserts. They suit offices, healthcare and education buildings that want a clean, modern frame matching the rest of the glazing.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Coverage around Coleraine includes the BT51, BT52 districts and nearby Ballymena, Derry / Londonderry, Newtownabbey. Coleraine is about 44 km from Derry / Londonderry, the largest town in our County Londonderry coverage.
After survey you get a fixed written quote for the agreed scope, so Coleraine budgets are not open-ended.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Coleraine around residents, staff or pupils, with out-of-hours options.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
We can survey and quote for retail and leisure units, schools and colleges and other building types in Coleraine.
30 and 60-minute ratings are common, in integrity or insulation classes depending on the glass. We confirm availability for the sizes you need.
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Coleraine is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Coleraine to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.