Cornwall aluminium fire-rated screens
We take aluminium fire-rated screens enquiries from across Cornwall, with surveys arranged in Truro, Redruth, Falmouth, St Austell, Camborne and the surrounding towns.
Quote for Cornwall
Tell us what you need. We reply with next steps and a guide price.

Towns we cover in Cornwall
Across Cornwall we can survey in Truro, Redruth, Falmouth, St Austell, Camborne and every district in the TR, PL, EX postcode areas.
Aluminium Fire-Rated Screens: an overview for Cornwall
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
- Fire-stopping and perimeter details
- Integrity and insulating glass to the system schedule
- Matching fire-rated doors within the system
Key checks for Cornwall projects
Matching non-rated glazing
Aluminium fire screens can be visually matched to non-rated partitions elsewhere, so a floor reads as one design while only some walls are fire-rated.
External use
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
Deflection and fixings
Head details and fixing centres come from the system documentation, especially beneath long-span slabs.
Regulations for Cornwall projects
England Which rules apply?
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Questions from Cornwall clients
Is aluminium suitable for fire-rated glazing?
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
Can aluminium fire screens be used outside?
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Will the frames match our other glazing?
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
Which parts of Cornwall do you cover?
All of it: Truro, Redruth, Falmouth, St Austell, Camborne and every district in the TR, PL, EX postcode areas.
Related services in Cornwall
What happens next
Start with the brief
Tell us the rating required, sizes and building type, or ask us to find out.
Survey
We visit Cornwall to measure, record existing marks and check the frames and substrate.
Written proposal
We set out the system, glass, evidence and programme, with a fixed price.
Complete and document
Work is completed to the manufacturer's details and documented for your records.