Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Kilmarnock calls for glazing tested to resist fire, our aluminium fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
Our Ayrshire coverage takes in Kilmarnock (KA3) and the neighbouring towns of Irvine, Ayr, Newton Mearns. Kilmarnock is the largest town in our Ayrshire coverage.
Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Every quote in Kilmarnock identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Kilmarnock around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Kilmarnock building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover schools and colleges, industrial units and other buildings in Kilmarnock.
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
Yes. We survey and install in Kilmarnock and across Ayrshire, including the KA3 district and nearby Irvine.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Kilmarnock confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.