Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →We provide fire glazing remedial works in Burntwood and across Staffordshire, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fire glazing remedial works are the repairs and replacements that bring glazed fire-resisting elements back into line with their required performance: replacing unsuitable glass, refitting beads and seals, sealing service penetrations, and replacing frames that cannot be shown to be rated.
Remedial glass and seals must suit the existing frame's evidence. Where that evidence is missing, we raise it before work starts.
Intumescent strips painted over during redecoration can be replaced without changing the glass.
Each completed item is photographed and cross-referenced to the original report so the action can be closed.
Our Staffordshire coverage takes in Burntwood (WS7) and the neighbouring towns of Lichfield, Cannock, Aldridge. Burntwood lies roughly 40 km from Stoke-on-Trent, within our Staffordshire coverage.
After survey you get a fixed written quote for the agreed scope, so Burntwood budgets are not open-ended.
We can phase work in Burntwood around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover hotels, offices and other buildings in Burntwood.
We explain the options: obtaining evidence from the manufacturer, a formal assessment, or replacing the frame with a tested system.
Yes, before and after for every item, plus a completion schedule.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Burntwood follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Burntwood and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.