Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Fire glazing remedial works in Wimbledon is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Fire glazing remedial works are the repairs and replacements that bring glazed fire-resisting elements back into line with their required performance: replacing unsuitable glass, refitting beads and seals, sealing service penetrations, and replacing frames that cannot be shown to be rated.
We price each defect separately so you can approve urgent items first.
We plan remedial programmes around residents, pupils or staff, with phasing and clear communication.
Cables and pipes through glazed screens and their surrounds must be fire-stopped with products tested for that application.
Survey visits can be arranged anywhere in Wimbledon, including the SW19, SW20, SW18, SM4, SW17, SW15 districts, and in nearby Morden, Mitcham, Putney. Wimbledon sits within our Greater London coverage, alongside Morden.
Every quote in Wimbledon identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Wimbledon building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Wimbledon around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for retail and leisure units, blocks of flats and other building types in Wimbledon.
Yes. Send the report and we will price the glazing-related actions item by item.
Yes. We prioritise by risk and agree phases with you.
Building work in Wimbledon follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Wimbledon and across Greater London, including the SW19 district and nearby Morden.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Wimbledon to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.