Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Our fire glazing remedial works service covers St Austell and neighbouring areas such as Truro and Newquay, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
We work from fire risk assessments, fire door inspection reports and our own surveys, pricing each item clearly and completing the work with photographs and a schedule you can file. Where an item cannot be fixed without evidence from a manufacturer or test body, we say so and set out the options.
Each completed item is photographed and cross-referenced to the original report so the action can be closed.
Cables and pipes through glazed screens and their surrounds must be fire-stopped with products tested for that application.
Remedial glass and seals must suit the existing frame's evidence. Where that evidence is missing, we raise it before work starts.
We cover St Austell and the surrounding postcode districts, including PL25, PL26. Nearby towns we also serve include Truro, Newquay, Falmouth. St Austell is about 34 km from Truro, the largest town in our Cornwall coverage.
If an existing frame in a St Austell building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so St Austell budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, schools and colleges and other buildings in St Austell.
Yes. We prioritise by risk and agree phases with you.
We explain the options: obtaining evidence from the manufacturer, a formal assessment, or replacing the frame with a tested system.
Yes. We survey and install in St Austell and across Cornwall, including the PL25 district and nearby Truro.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in St Austell confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.