Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →We provide fire door vision panels in Aldridge and across West Midlands, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
Ordinary float or toughened glass in a fire door vision panel is a serious defect. We replace it with fire-resistant glass compatible with the door.
Our West Midlands coverage takes in Aldridge (WS9, WS4, WS8, B74) and the neighbouring towns of Walsall, Bloxwich, Sutton Coldfield. Aldridge is about 14 km from Birmingham, the largest town in our West Midlands coverage.
After survey you get a fixed written quote for the agreed scope, so Aldridge budgets are not open-ended.
Every quote in Aldridge identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Aldridge building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover hotels, public buildings and other buildings in Aldridge.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Aldridge confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.