Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →Our fire door vision panels service covers Oxford and neighbouring areas such as Abingdon and Didcot, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
A fire door vision panel is the glazed opening in a fire door that lets people see through it. It is part of the door's fire rating: the glass, beads, glazing seals and the size and position of the opening all have to match the door's test or certification evidence.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
We photograph each panel before and after and note the glass marks, so your fire door records stay complete.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Oxford, including the OX1, OX2, OX4, OX3 districts, and in nearby Abingdon, Didcot, Witney. Oxford is the largest town in our Oxfordshire coverage.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Oxford building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can survey and quote for retail and leisure units, schools and colleges and other building types in Oxford.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Building work in Oxford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Oxford and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.