Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →Looking for fire door vision panels in York? We survey, supply and install tested fire-rated glazing for hotels, blocks of flats and other buildings in and around York, including the YO1 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
A new aperture can invalidate a door's certification unless the manufacturer's instructions allow it. We check before cutting.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Whether the building is in central York or the wider YO1, YO10, YO31, YO24 districts, we can survey and quote. We also cover Selby, Harrogate, Goole. York is the main town we cover in North Yorkshire.
If an existing frame in a York building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover hotels, blocks of flats and other buildings in York.
Once we know the door type and glass size, standard integrity panes can often be supplied quickly; insulating glass may take longer to cut to size.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in York and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.