Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →We provide fire door vision panels in Sittingbourne and across Kent, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
A fire door vision panel is the glazed opening in a fire door that lets people see through it. It is part of the door's fire rating: the glass, beads, glazing seals and the size and position of the opening all have to match the door's test or certification evidence.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Sittingbourne, including the ME10, ME9 districts, and in nearby Faversham, Gillingham, Chatham. Sittingbourne lies roughly 17 km from Maidstone, within our Kent coverage.
If an existing frame in a Sittingbourne building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Sittingbourne around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Fire door vision panels applies to many building types in Sittingbourne, including retail and leisure units and industrial units.
Yes. The replacement must be fire-resistant glass of a type the door's evidence allows, fitted with the correct beads and seals.
It may provide integrity, but it often fails impact safety requirements. Replacement with modern fire glass is usually recommended.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Sittingbourne follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Sittingbourne confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.