Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →When a fire strategy, inspection report or building control comment in Southampton calls for glazing tested to resist fire, our fire door vision panels service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
A fire door vision panel is the glazed opening in a fire door that lets people see through it. It is part of the door's fire rating: the glass, beads, glazing seals and the size and position of the opening all have to match the door's test or certification evidence.
We photograph each panel before and after and note the glass marks, so your fire door records stay complete.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
Our Hampshire coverage takes in Southampton (SO15, SO14, SO19, SO17, SO18, SO16) and the neighbouring towns of Hythe, Totton, Eastleigh. Southampton is the main town we cover in Hampshire.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Southampton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover healthcare buildings, schools and colleges and other buildings in Southampton.
Yes. The replacement must be fire-resistant glass of a type the door's evidence allows, fitted with the correct beads and seals.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Building work in Southampton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Southampton depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Southampton and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.