Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →We provide fire door vision panels in Mitcham and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
Whether the building is in central Mitcham or the wider CR4, SM4, SW19, SW17, SW16, SM5 districts, we can survey and quote. We also cover Morden, Wimbledon, Streatham. Mitcham is one of the Greater London districts we cover.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can phase work in Mitcham around residents, staff or pupils, with out-of-hours options.
Every quote in Mitcham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover offices, student accommodation and other buildings in Mitcham.
Once we know the door type and glass size, standard integrity panes can often be supplied quickly; insulating glass may take longer to cut to size.
Yes. The replacement must be fire-resistant glass of a type the door's evidence allows, fitted with the correct beads and seals.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Mitcham and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.