Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →When a fire strategy, inspection report or building control comment in London calls for glazing tested to resist fire, our fire door vision panels service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in London identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in London around residents, staff or pupils, with out-of-hours options.
If your fire door inspection report lists vision panel defects, send it to us and we will quote item by item.
A new aperture can invalidate a door's certification unless the manufacturer's instructions allow it. We check before cutting.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Whether the building is in central London or the wider EC1A, EC1M, EC1N, EC1R, EC3, EC4A districts, we can survey and quote. We also cover Westminster, Pimlico, Islington. London is the main town we cover in Greater London.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover offices, student accommodation and other buildings in London.
Once we know the door type and glass size, standard integrity panes can often be supplied quickly; insulating glass may take longer to cut to size.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in London and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.