Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →When a fire strategy, inspection report or building control comment in Windsor calls for glazing tested to resist fire, our fire door vision panels service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
A new aperture can invalidate a door's certification unless the manufacturer's instructions allow it. We check before cutting.
Ordinary float or toughened glass in a fire door vision panel is a serious defect. We replace it with fire-resistant glass compatible with the door.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Coverage around Windsor includes the SL4, SL3, SL1 districts and nearby Slough, Egham, Staines-upon-Thames. Windsor lies roughly 26 km from Reading, within our Berkshire coverage.
If an existing frame in a Windsor building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Windsor identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover offices, industrial units and other buildings in Windsor.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Yes. The replacement must be fire-resistant glass of a type the door's evidence allows, fitted with the correct beads and seals.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Windsor follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Windsor and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.