Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Fire-rated escape route glazing in Chippenham is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
If an existing frame in a Chippenham building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Chippenham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
Our Wiltshire coverage takes in Chippenham (SN15) and the neighbouring towns of Trowbridge, Bath, Yate. Chippenham lies roughly 26 km from Swindon, within our Wiltshire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover hotels, blocks of flats and other buildings in Chippenham.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Chippenham depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Chippenham confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.