Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Warwickshire · CV34

Stair, Lobby & Corridor Glazing in Warwick

Our fire-rated escape route glazing service covers Warwick and neighbouring areas such as Royal Leamington Spa and Kenilworth, with every job built around a tested system.

E 30 – EI 60CV34England

Quote for Warwick

Tell us what you need. We reply with next steps and a guide price.

Stair, Lobby & Corridor Glazing in Warwick: what's included

Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.

  • Stair enclosure screens
  • Evidence for the fire safety file
  • Insulating glass where escape routes require it
  • Lobby and corridor screens with doors

Where we work around Warwick

Whether the building is in central Warwick or the wider CV34, CV31, CV32 districts, we can survey and quote. We also cover Royal Leamington Spa, Kenilworth, Stratford-upon-Avon. Warwick is about 28 km from Nuneaton, the largest town in our Warwickshire coverage.

Before you order fire-rated escape route glazing: what matters

Smoke control

Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.

Integrity versus insulation

Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.

Stair enclosures

Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.

Which rules apply to fire-rated escape route glazing in Warwick?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

How we work in Warwick

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Warwick budgets are not open-ended.

Work around occupied buildings

We can phase work in Warwick around residents, staff or pupils, with out-of-hours options.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Building types we cover in Warwick

Sector guides below cover offices, retail and leisure units and other buildings in Warwick.

FAQs for Warwick

Can work be done while the building is occupied?

Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.

Can I use glass on a fire escape route?

Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.

Which rules apply to fire-rated glazing in Warwick?

Building work in Warwick follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Do you work on occupied buildings in Warwick?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Warwick

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

From enquiry to handover in Warwick

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Warwick and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote