Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →For Wallsend buildings, we supply, replace and check fire-rated escape route glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Wallsend or the wider NE28, NE31, NE6, NE32, NE7, NE2 districts, we can survey and quote. We also cover Hebburn, Jarrow, Felling. Newcastle upon Tyne, around 5 km from Wallsend, is the largest town in the same coverage area.
After survey you get a fixed written quote for the agreed scope, so Wallsend budgets are not open-ended.
We can phase work in Wallsend around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Fire-rated escape route glazing applies to many building types in Wallsend, including industrial units and blocks of flats.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Wallsend and across Tyne and Wear, including the NE28 district and nearby Hebburn.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Wallsend confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.