What our fire-rated escape route glazing service includes in Nottingham

Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.

  • Stair enclosure screens
  • Corridor subdivision doors with vision panels
  • Smoke seals and closers on doors
  • Evidence for the fire safety file

Before you order fire-rated escape route glazing: what matters

Smoke control

Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.

Keep routes clear

We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.

Integrity versus insulation

Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.

Which rules apply to fire-rated escape route glazing in Nottingham?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Nottingham coverage and nearby towns

Our Nottinghamshire coverage takes in Nottingham (NG1, NG3, NG7, NG2, NG8) and the neighbouring towns of West Bridgford, Arnold, Hucknall. Nottingham is the largest town in our Nottinghamshire coverage.

How we work in Nottingham

Work around occupied buildings

We can phase work in Nottingham around residents, staff or pupils, with out-of-hours options.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Rated systems, not just rated glass

Every quote in Nottingham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Sectors we cover in Nottingham

Fire-rated escape route glazing applies to many building types in Nottingham, including student accommodation and hotels.

Stair, Lobby & Corridor Glazing: Nottingham questions

Do escape route doors need vision panels?

Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.

Why would a corridor need insulating glass?

Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.

Can you price fire-rated escape route glazing in Nottingham from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Which rules apply to fire-rated glazing in Nottingham?

Building work in Nottingham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Nottingham

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

From enquiry to handover in Nottingham

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Nottingham and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote