Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →If a building in Bridgend needs fire-rated escape route glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
After survey you get a fixed written quote for the agreed scope, so Bridgend budgets are not open-ended.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Bridgend identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Survey visits can be arranged anywhere in Bridgend, including the CF31, CF32, CF35 districts, and in nearby Maesteg, Tonypandy, Rhondda. Rhondda, around 19 km from Bridgend, is the largest town in the same coverage area.
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
We can survey and quote for offices, blocks of flats and other building types in Bridgend.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Yes. We survey and install in Bridgend and across Mid Glamorgan, including the CF31 district and nearby Maesteg.
Bridgend is in Wales, where the Welsh Approved Document B applies to building work and the Regulatory Reform (Fire Safety) Order 2005 covers occupied premises.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Bridgend confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.