Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →From the PR25 district outwards, we arrange fire-rated escape route glazing for buildings across Leyland, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
Survey visits can be arranged anywhere in Leyland, including the PR25, PR26, PR5 districts, and in nearby Chorley, Preston, Blackburn. Leyland lies roughly 7 km from Preston, within our Lancashire coverage.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Every quote in Leyland identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Leyland building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Leyland budgets are not open-ended.
Fire-rated escape route glazing applies to many building types in Leyland, including public buildings and industrial units.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Survey timing in Leyland depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We survey and install in Leyland and across Lancashire, including the PR25 district and nearby Chorley.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Leyland confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.