Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →For Harpenden buildings, we supply, replace and check fire-rated escape route glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
We can phase work in Harpenden around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Harpenden budgets are not open-ended.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
We cover Harpenden and the surrounding postcode districts, including AL5, AL3. Nearby towns we also serve include St Albans, Luton, Hemel Hempstead. Harpenden is about 18 km from Watford, the largest town in our Hertfordshire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for industrial units, hotels and other building types in Harpenden.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Survey timing in Harpenden depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Harpenden follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Harpenden confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.