Learn more →Fire-rated escape route glazing in Fulham is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Survey visits can be arranged anywhere in Fulham, including the SW6, SW5, W6, W14, SW10, W8 districts, and in nearby Chelsea, Putney, Battersea. Fulham is one of the Greater London districts we cover.
Every quote in Fulham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Fulham building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover offices, retail and leisure units and other buildings in Fulham.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Building work in Fulham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Fulham and across Greater London, including the SW6 district and nearby Chelsea.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Fulham and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.