Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →For Kendal buildings, we supply, replace and check fire-rated escape route glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Survey visits can be arranged anywhere in Kendal, including the LA9, LA8 districts, and in nearby Morecambe, Lancaster, Barrow-in-Furness. Kendal lies roughly 64 km from Carlisle, within our Cumbria coverage.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
If an existing frame in a Kendal building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Kendal budgets are not open-ended.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Sector guides below cover hotels, public buildings and other buildings in Kendal.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Survey timing in Kendal depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Kendal follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Kendal to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.