Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →For Coleraine buildings, we supply, replace and check fire-rated escape route glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Coverage around Coleraine includes the BT51, BT52 districts and nearby Ballymena, Derry / Londonderry, Newtownabbey. Coleraine lies roughly 44 km from Derry / Londonderry, within our County Londonderry coverage.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Every quote in Coleraine identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Coleraine around residents, staff or pupils, with out-of-hours options.
We can survey and quote for hotels, schools and colleges and other building types in Coleraine.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Coleraine is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Coleraine confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.