Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Berkshire · RG45

Stair, Lobby & Corridor Glazing for Crowthorne buildings

When a fire strategy, inspection report or building control comment in Crowthorne calls for glazing tested to resist fire, our fire-rated escape route glazing service covers survey, supply and installation.

E 30 – EI 60RG45England

Quote for Crowthorne

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated escape route glazing in Crowthorne

We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.

  • Stair enclosure screens
  • Smoke seals and closers on doors
  • Evidence for the fire safety file
  • Insulating glass where escape routes require it

Where we work around Crowthorne

Our Berkshire coverage takes in Crowthorne (RG45, GU47, RG12, GU46, RG40) and the neighbouring towns of Sandhurst, Yateley, Camberley. Crowthorne is about 16 km from Reading, the largest town in our Berkshire coverage.

Before you order fire-rated escape route glazing: what matters

Inspection regimes

In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.

Vision through doors

Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.

Integrity versus insulation

Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.

Which rules apply to fire-rated escape route glazing in Crowthorne?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

What you can expect in Crowthorne

Rated systems, not just rated glass

Every quote in Crowthorne identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Crowthorne budgets are not open-ended.

Honest about unknowns

If an existing frame in a Crowthorne building has no traceable evidence, we say so and price the options rather than guess.

Building types we cover in Crowthorne

We can survey and quote for retail and leisure units, public buildings and other building types in Crowthorne.

Stair, Lobby & Corridor Glazing: Crowthorne questions

Can work be done while the building is occupied?

Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.

Do escape route doors need vision panels?

Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.

Do you work on occupied buildings in Crowthorne?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Can you price fire-rated escape route glazing in Crowthorne from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Crowthorne

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Crowthorne job runs

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Measure and check

We measure each opening in Crowthorne and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.