Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Aberdeen, Aberdeenshire and Moray · AB10

Stair, Lobby & Corridor Glazing — Aberdeen and AB10

If a building in Aberdeen needs fire-rated escape route glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60AB10Scotland

Quote for Aberdeen

Tell us what you need. We reply with next steps and a guide price.

Stair, Lobby & Corridor Glazing in Aberdeen: what's included

We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.

  • Insulating glass where escape routes require it
  • Corridor subdivision doors with vision panels
  • Lobby and corridor screens with doors
  • Smoke seals and closers on doors

How we work in Aberdeen

Honest about unknowns

If an existing frame in a Aberdeen building has no traceable evidence, we say so and price the options rather than guess.

Rated systems, not just rated glass

Every quote in Aberdeen identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Scotland rules applied

Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.

Key checks for Aberdeen projects

Integrity versus insulation

Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.

Vision through doors

Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.

Smoke control

Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.

Aberdeen coverage and nearby towns

Whether the building is in central Aberdeen or the wider AB10, AB11, AB12, AB24, AB25, AB16 districts, we can survey and quote. We also cover Arbroath, Dundee, Elgin. Aberdeen is the main town we cover in Aberdeen, Aberdeenshire and Moray.

Which rules apply to fire-rated escape route glazing in Aberdeen?

Scotland Which rules apply?

In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.

For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.

Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.

Sectors we cover in Aberdeen

Sector guides below cover healthcare buildings, schools and colleges and other buildings in Aberdeen.

Stair, Lobby & Corridor Glazing: Aberdeen questions

Why would a corridor need insulating glass?

Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.

Do escape route doors need vision panels?

Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.

Do you carry out fire-rated escape route glazing in Aberdeen?

Yes. We survey and install in Aberdeen and across Aberdeen, Aberdeenshire and Moray, including the AB10 district and nearby Arbroath.

How quickly can you survey in Aberdeen?

Survey timing in Aberdeen depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Aberdeen

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Aberdeen to measure, record existing marks and check the frames and substrate.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote